There is no fixed calendar interval. A filter should be changed when it is full, and the pressure gauge tells you when that is.
Watch the differential pressure
- Note the reading across the housing when the filter is new and clean.
- A common rule of thumb is to change when the reading has risen by about 1 bar (about 15 psi), or sooner if flow drops below what the process needs.
- Never run past the maximum differential pressure on the datasheet: the element can bypass or rupture.
Other signs it is time
- Flow is falling at the same pump setting
- Filtered liquid is cloudier or contains particles
- Visible damage, leaks around the seal or a distorted element
Habits that help
- Log the pressure at each shift to learn your normal interval
- Keep spare filters and gaskets on hand
- Fit a coarser filter upstream to protect the fine stage